Skip to content

Gantry CT

RMCT7000

Gantry CT for long and heavy workpieces

Royma RMCT7000 Gantry CT system
Sample size, standard configuration
2000 × 420 × 160 mm
Closed microfocus tube, 150 W
200 kV
Measurement precision, depending on thickness and material
35 µm
X-ray leakage
< 0.5 µSv/h

Overview

The part rests. The CT moves.

Long and heavy workpieces are hard to rotate on a turntable. In the RMCT7000 the part lies flat, and source and detector rotate around it on a gantry ring.

Battery modules, long profiles and tube-shaped components are scanned without clamping or turning. The system works at the line or in the line.

The standard machine is 7.2 m long. Small parts that rotate easily are inspected faster in a cabinet system.

Features

Made for long parts.

Scan lying flat

Load the part as it comes off the line. The standard gantry takes samples up to 2000 × 420 × 160 mm; the length can be adapted for inline machines.

Choose the scan

Trade speed against completeness. Circular, segment and limited-angle CT scans are available, plus a fast 2D scan.

Configure the power

Match the source to the part. The standard configuration uses a 200 kV closed microfocus tube. A large-workpiece configuration works with up to 450 kV, for parts up to 1010 × 1980 mm and 300 kg.

Measure in production

Get dimensions as well as defects. Measurement precision is 35 µm, depending on the thickness and material of the object.

Integrate the workflow

Connect the scan to your process. The software covers acquisition, reconstruction, 3D visualisation, modules for scan automation and customisable analysis.

Safe at the line

Install it on the shop floor. The lead cabinet has a safety lock, is CE certified and keeps X-ray leakage below 0.5 µSv/h.

Specifications

Technical data.

Standard at-line and inline configuration
X-ray sourceClosed microfocus tube, 200 kV, 150 W
DetectorFlat panel, 139 µm pixels, 3072 × 3072, 427 × 427 mm
Maximum FDD1280 mm, customisable
Maximum sample size2000 × 420 × 160 mm, length customisable for inline machines
Measurement precision35 µm, depending on object thickness and material
Operation modes3D CT inline or at-line, 2D fast scan, circular, segment and limited-angle scan
Large-workpiece configuration
Tube voltage180 / 200 / 225 / 300 / 450 kV
Sample1010 × 1980 mm, 300 kg
Installation
Machine size7200 × 2500 × 2700 mm as standard, customisable
Weight15 000 kg
Gantry frameSteel or granite
X-ray leakage< 0.5 µSv/h
CertificationCE

Applications

Where it is used.

Internal structure and connections of battery modules; defects and dimensions in long workpieces.

Downloads

Data sheet on request.

We send the current RMCT7000 data sheet together with a first assessment of your part.

Request data sheet

Let's solve your inspection challenge.

Talk to an expert